This is an old revision of the document!
1. Download the firmware designed as per your request in your PC.
2. Download and install Atmel Flip software, https://www.microchip.com/en-us/development-tool/flip.
3. Prepare the proper cable to be connected to the red box position on the sCLK-EX.
The following image is the pin map to make the proper cable, and refer to the connector part numbers,
And connect the cable from the PC’s USB port to the red position on the sCLK-EX.
4. Please power on the tX-USBultra. (If you have the sCLK-EX installed in the PC, do not use the PC's power for the firmware upgrade, please use the separate soley power to the sCLK-EX instead.)
5. Please run Atmel Flip program and click the green marked icon and open the device selection→Atmega8U2→Ok.
6. And click the red marked icon, select USB→ USB Port Connection→Open.
7. Please click ‘file’ menu and enter ‘Load HEX file’ and select the downloaded F/W file and click ‘OK’ button to load F/W file and Run.
8. The Programming status will be shown as following image.
9. Once F/W programming is completed well, ‘Verify Pass’ comment will be shown as the below image.
10. Please exit Flip program and power off and on the tX-USBultra.